Fittings Multilayer composite pipe Pressfitting 16x2 20x2 26x3 32x3 DVGW TH,U,B


Item number 457000

01.01.1970

${ $store.getters.currentItemVariation.variation.availability.names.name }

* Incl. VAT excl. Shipping

Press fitting system for multilayer composite pipes

DVGW-tested


The NTM high performance insulated multi-layer composite pipes with "winny al" can be used with compression fittings.

Fitting made of CW617N brass (new DVGW)

high corrosion resistance

unpressed guaranteed leakage - unpressed connections are detected immediately

2 O-rings made of peroxide cross-linked EPDM (high tightness)

Inspection openings show the correct fit of the composite pipe

Quality standard UNI EN ISO 21003-3

DVGW approval and DIN tested

for use in heating, sanitary and drinking water systems

pressable with TH, U and H contour

Fittings can also be supplied with blue plastic part


Please note the following versions in the available sizes:

45700 - Adapter with male thread

  • 16 X 1/2"
  • 16 X 3/4"
  • 20 X 1/2"
  • 20 X 3/4"
  • 26 X 3/4"
  • 26 X 1"
  • 32 X 1"
  •  

45701 - Coupling

  • Ø 16-16
  • Ø 20-20
  • Ø 26-26
  • Ø 32-32
  • reduced Ø 20-16
  • reduced Ø 26-16
  • reduced Ø 26-20
  • reduced Ø 32-20
  • reduced Ø 32-26

45702 - Adapter with female thread

  •  
  • 16 X 1/2"
  • 16 X 3/4"
  • 20 X 1/2"
  • 20 X 3/4"
  • 26 X 3/4"
  • 26 X 1"
  • 32 X 1"

45703 - Angle

  • 90° Ø 16-16
  • 90° Ø 20-20
  • 90° Ø 26-26
  • 90° Ø 32-32

45704 - Transition angle with male thread

  • 16 X 1/2"
  • 16 X 3/4"
  • 20 X 1/2"
  • 20 X 3/4"
  • 26 X 3/4"
  • 26 X 1"
  • 32 X 1"

45705 - Transition angle with female thread

  • Ø 16 X 1/2"
  • Ø 16 X 3/4"
  • Ø 20 X 1/2"
  • Ø 20 X 3/4"
  • Ø 26 X 3/4"
  • Ø 26 X 1"
  • Ø 32 X 1"

45706 - Wall plate

  • Ø 16 x 1/2"
  • Ø 16 x 3/4"
  • Ø 20 x 1/2"
  • Ø 20 x 3/4"

45707 - T-piece

  • with equal departures
  • Ø 16-16-16
  • Ø 20-20-20
  • Ø 26-26-26
  • Ø 32-32-32

  • Middle aisle extended
  • Ø 16-20-16
  • Ø 20-26-20
  • Ø 20-32-20

  • Reduced centre aisle
  • Ø 20-16-20
  • Ø 26-16-26
  • Ø 26-20-26
  • Ø 32-16-32
  • Ø 32-20-32
  • Ø 32-26-32

  • reduced
  • Ø 20-16-16
  • Ø 20-20-16
  • Ø 26-16-16
  • Ø 26-16-20
  • Ø 26-20-16
  • Ø 26-20-20
  • Ø 26-26-16
  • Ø 26-26-20
  • Ø 32-20-20
  • Ø 32-20-26
  • Ø 32-26-26
  • Ø 32-32-20
  • Ø 32-32-26

45708 - T-piece with male thread

  • Ø 16 X 1/2" X 16
  • Ø 20 X 1/2" X 20
  • Ø 20 X 3/4" X 20
  • Ø 26 X 3/4" X 26
  • Ø 26 X 1" X 26
  • Ø 32 X 1" X 32

45709 - T-piece with female thread

  • Ø 16 X 1/2" X 16
  • Ø 20 X 1/2" X 20
  • Ø 20 X 3/4" X 20
  • Ø 26 X 3/4" X 26
  • Ø 26 X 1" X 26
  • Ø 32 X 1" X 32

45710 - Cross piece

  • Ø 16 x 4 times
  • Ø 20 x 4 times

45726 - Double corner bracket with female thread

  • 16 x 1/2" x 16
  • 20 x 1/2" x 20

45728 - Angle with mounting plate

  • Ø 16 x 1/2"

45735 - Transition IG flat sealing

  • Ø 16 x 1/2"
  • Ø 16 x 3/4"
  • Ø 20 x 1/2"
  • Ø 20 x 3/4"
  • Ø 26 x 3/4"

4755 - Transition angle flat sealing

  • Ø 16 x 1/2"
  • Ø 16 x 3/4"
  • Ø 20 x 1/2"
  • Ø 20 x 3/4"
  • Ø 26 x 3/4"

4778 - Mounting set with ceiling bracket

  • Ø16 x 1/2"

4750 - Multi-layer composite pipe without insulation "winny al

  • 16 x 2,0 - 1m in one piece up to 100m
  • 16 x 2,0 - 10m
  • 16 x 2,0 - 25m
  • 16 x 2,0 - 50m
  • 16 x 2,0 - 100m
  • 20 x 2,0 - 1m in one piece up to 100m
  • 20 x 2,0 - 10m
  • 20 x 2,0 - 25m
  • 20 x 2,0 - 50m
  • 20 x 2,0 - 100m
  • 26 X 3,0 - 1m in one piece up to 50m
  • 26 X 3,0 - 10m
  • 26 X 3,0 - 25m
  • 26 X 3,0 - 50m
  • 32 X 3,0 - 1m in one piece up to 50m
  • 32 X 3,0 - 10m
  • 32 X 3,0 - 25m
  • 32 X 3,0 - 50m

4752 - Multi-layer composite pipe with 6mm blue insulation "winny al

  • 16 x 2,0 - 1m in one piece up to 50m
  • 16 x 2,0 - 25m
  • 16 x 2,0 - 50m
  • 20 x 2,0 - 1m in one piece up to 50m
  • 20 x 2,0 - 25m
  • 20 x 2,0 - 50m
  • 26 X 3,0 - 1m in one piece up to 50m
  • 26 x 3,0 - 25m
  • 26 x 3,0 - 50m
  • 32 X 3,0 - 1m in one piece up to 25m
  • 32 x 3,0 - 25m

4753 - Multi-layer composite pipe with 6mm red insulation "winny al

  • 16 x 2,0 - 1m in one piece up to 50m
  • 16 x 2,0 - 25m
  • 16 x 2,0 - 50m
  • 20 x 2,0 - 1m in one piece up to 50m
  • 20 x 2,0 - 25m
  • 20 x 2,0 - 50m
  • 26 X 3,0 - 1m in one piece up to 50m
  • 26 x 3,0 - 25m
  • 26 x 3,0 - 50m
  • 32 X 3,0 - 1m in one piece up to 25m
  • 32 x 3,0 - 25m

simplified installation instructions

Cut the multi-layer composite pipe to length perpendicular to its longitudinal axis. Remove burrs and chips.

Calibrate the pipe with a tool that has no sharp edges so as not to cut the plastic layer, as this could affect the pressure tightness (calibration tool).

Apply grease or an equivalent lubricant to the end of the pipe to make it easier to fit the O-rings and keep them elastic. Then insert the pipe into the fitting as far as it will go; the insertion depth can be checked through the slots in sleeve A. The fitting can be inserted through the slots in sleeve A. The fitting can then be inserted through the slots in sleeve A.

Place the pliers according to your own marking and press the sleeve with the tool provided for this purpose. Make sure that the longitudinal axis of the pipe is exactly perpendicular to the pliers. For our fittings pliers of type TH - U can be used).

 

 

Please note that you will always use press fittings and system pipes for your installation work.

A DVGW-approved and thus safe, sufficiently tested pipe connection always consists of both components, the pipe and the screw fitting tested with this pipe. If a fitting is processed with a "foreign" pipe, there is no guarantee of tightness and compatibility, as it is an untested and non-approved connection, even if both products are DVGW-approved.

With regard to the professional planning, installation, acceptance and management of the water supply, heating and sanitary systems, the following valid regulations must be observed: UNI EN 806 : 2088 e UNI 9182 : 2010

Please note that the installation of all components must be carried out by a technically competent person. The installation must also be documented and stored in a pressure test protocol in accordance with the manufacturer's and legislator's specifications. The detailed installation instructions as well as the print test protocol can be downloaded from our homepage. Failure to follow these instructions may result in the rejection of any warranty claims.

Have fun pressing!